@thesis{thesis, author={Hariyanto Agung and Lestari Sri Rahayu Dwi}, title ={ANALISIS JARINGAN DISTRIBUSI DI DAERAH PERUMAHAN LA DIVA GREEN HILL MENGANTI SURABAYA}, year={2017}, url={http://156.67.221.169/1044/}, abstract={In the system of distribution of electrical energy that starts from the substation to a certain point will have a value of voltage drop. To supply a residential area just needs to be supplied from a single feeder. Feeder feeder used is incorporated in the New Light of substation Karang Pilang and has a channel length overall is 29,100 kms, while the residential area will be supplied from the feeders are Housing La Diva Green Hill Menganti Surabaya. New Light feeder and Housing La Diva Green Hill Menganti Surabaya is still in the working area of PT PLN (Persero) Surabaya West Area. The analysis will be discussed in this thesis is the value of the voltage drop, power flow flowing to the housing area by using power system analysis software (ETAP 12.6.0). Note that the voltage drop standards set by PLN is + 5% to -10% of nominal voltage.} }