@thesis{thesis, author={ISHYAFAPUTRO BISMO and Kurniasih Novi}, title ={ANALISIS SUSUT DISTRIBUSI 20 KV PT PLN (PERSERO) ULP SANDAI TERHADAP PROGRAM DEDIESELISASI PLTD AUR KUNING}, year={2022}, url={http://156.67.221.169/5417/}, abstract={PLN?s attempt due to RUPTL 2021 ? 2030 concerning reducing the emission of grennhouse and reducing the cost of production by deactivation PLTD through dedieselization program and grid to larger system through substation. However, the dedieselization program needs to be calculated in terms of distribution losses. By deactivating PLTD Aur Kuning and gridding to Tayan Subsation, its expected to revise the losses of ULP Sandai. At ULP Sandai, the cumulative losses before dedieselization in December 2021 was 9.45% from the target of 9.20%. The cumulative losses until April 2022 was 8.51% from the target of 8.40%. Based on ETAP simulation, if the Tayan Substation grid is carried out, it has a smaller losses when compared to the supply from the PLTD Aggreko, with the loss saving value of 8,696.85 kWh which if converted into rupiah is Rp 12,564,345.44 assuming a selling price of Rp 1,444.7 per kWh. The impact of dedieselization on losses of ULP Sandai is that cumulative losses in December 2021 have improved from 9.45% to 9.37% but have not met the target of 9.20%. The cumulative losses until April 2022 was better from 8.51%, down to 8.25% and has met the target of 8.40%. The dedieselization of PLTD Aur Kuning can save cumulatively Rp 2,034,147,837 or reduce costs by 3.79% compared to before dedieselization} }