@thesis{thesis, author={Pariaman Henry and Razak Muhammad Andi}, title ={ANALISIS ENERGI DAN EKSERGI PEMBANGKIT LISTRIK TENAGA GAS BLOK 3.2 UNIT PEMBANGKITAN MUARA TAWAR}, year={2019}, url={http://156.67.221.169/577/}, abstract={This research is about exergy efficiency and energy efficiency in a Gas Power Plant. Energy analysis is more quantitative while exergy analysis is almost the same but with qualitative additions. In the Muara Tawar PLTG there has never been an exergy analysis on the generator so that research needs to be done here to find out the strategic value of each component. The exergy flow rate compressor, combustion chamber, and gas turbine inlet and outlet calculation based on physical exergy dan chemical exergy. The exergy destruction calculation based on the difference betwen exergy flow in and exergy flow out each component. To get a good calculation the author uses data from the performance test to get maximum results on the ability of the PLTG to be calculated. It was found that in block 3.2 of the Muara Tawar PLTG, the exergy efficiency was 25.59%. Whereas for thermal efficiency it gets a value of 30.03%.} }