@thesis{thesis, author={Hendri Hendri}, title ={Analisa Getaran Pada Bearing Pompa Sentrifugal Untuk Kondisi Monitoring}, year={2017}, url={http://eprints.polbeng.ac.id/8688/}, abstract={Centrifugal pumps have a working principle of moving fluid flow from one place to another. This allows the pump's suppressed power to decrease. Falling pump performance is often a serious problem and undermines overall system performance. One indication of the cause of the fall in pump performance is the effect of vibration on the bearings. This research will analyze the shape of vibration, by knowing the value of threshold of vibration in accordance with ISO 2372-viberation severity standard. Of the three pumps the 101-P-7-A pump and the 101-P-4-B pumps have low vibration values of 0.28 - 4.50. While the pump vibration value of 101-P-5-B has a high vibration value of 7.10 - 11.2.} }