DETAIL DOCUMENT
Analisis Kinerja PLTS On-Grid 200 kWp di Bandar Udara Sultan Muhammad Salahudin Bima
Total View This Week0
Institusion
Institut Teknologi Perusahaan Listrik Negara
Author
Fadhilah, Annisyah
Hafidz, Mohammad
Subject
Teknik Elektro 
Datestamp
2019-12-05 12:39:11 
Abstract :
Sultan Muhammad Salahuddin Bima Airport Solar Power Plant (PLTS) is one of the power plants built to meet 20% of the airport?s needs and indirectly reduce fuel consumption for PLN power plants. PLTS is connected to the PLN low voltage electricity network and works with the ON-Grid system. Since PLTS is operating in May 2017 there is still no know Performance Ratio (PR) which is a performance parameter of a PLTS, so it is necessary to analyze the performance of Sultan Muhammad Salahuddin Bima Airport PLTS. To find out the value of performance ratio (PR), radiation, temperatere, current and voltage measurements are calculated so that the power value is obtained based on the calculation. Power values based on calculations obtained the value of Performance Ratio (PR) on April 15, 2019 and April 16, 2019 are 83% and 65%. The low value of Performance Ratio (PR) can be caused by environmental factors, namely weather factors, irradiation and shading. In addition, an analysis of the benefits of the construction of Sultan Muhammad Salahuddin Bima Airport PLTS was carried out. 