DETAIL DOCUMENT
ANALISIS DAN PENANGANAN TERJADINYA AUTOMATIC SHUTDOWN PADA AUXILIARY POWER UNIT BOEING 737-800 NG DI HANGGAR 4 PT. GMF AEROASIA
Total View This Week0
Institusion
INSTITUT TEKNOLOGI DIRGANTARA ADISUTJIPTO
Author
IMADDUDIN, RIZKI
Subject
T Technology (General) 
Datestamp
2024-04-25 03:54:56 
Abstract :
On the Boeing 737-800 NG aircraft, there is an auxiliary power unit that functions to supply pneumatic and electrical equipment both on the ground and in the air. In addition, the auxiliary power unit is also useful for starting aircraft engines. Auxiliary power units produce pneumatics for the air conditioning system on aircraft, as well as generate electricity for electricity on aircraft such as the lightning system on aircraft. This study aims to determine the cause of the auxuliary power unit experiencing automatic shutdown in hangar 4 PT. GMF AeroAsia using fault tree analysis method. During the inspection of the problem, a BITE-test is carried out to identify the cause of the problem. Then it was found that the cause of the automatic shutdown of the auxiliary power unit was high oil temperature. After the cause is found, then an inspection of the oil cooler is carried out according to the FIM. During the inspection of the oil cooler, it was found that there was corrosion on the surface of the air fins. So that makes the oil cooler not work optimally and must be replaced. After replacing the oil cooler, it is continued by analyzing the causes of failure that may arise using the fault tree analysis method. The result is 6 basic events, namely Clooged/Dirty, Oil Leak, Silver Particle, Large Metal Particle, Valve Stuck, Valve Leak. 