DETAIL DOCUMENT
MPN Coliform PADA AIR MINUM ISI ULANG DI KECAMATAN SAMBUNG MAKMUR
Total View This Week0
Institusion
Sekolah Tinggi Ilmu Kesehatan Borneo Lestari
Author
Nor Yatun, NY
Putri Kartika Sari (010809006), PKS
Dewi Ramadhani (010714055), DR
Subject
D3 TLM, AAK Borneo Lestari 
Datestamp
2019-08-06 02:07:04 
Abstract :
ABSTRAK MPN Coliform PADA AIR MINUM ISI ULANG DI KECAMATAN SAMBUNG MAKMUR Nor Yatun Putri Kartika Sari, Dewi Ramadhani Air minum adalah air yang melalui proses pengolahan atau tanpa proses pengolahan yang memenuhi syarat kesehatan dapat langsung diminum. Menurut Menteri Kesehatan Republik Indonesia Nomor 492/Menkes/PER/1V/2010 persyaratan kualitas air minum meliputi persyaratan bakteriologis, kimia, fisik dan radiologi. Penelitian ini bertujuan untuk mengetahui nilai MPN Coliform pada air minum isi ulang dan sumbernya di Kecamatan Sambung Makmur. Penelitian ini bersifat survey deskriftif dengan rancangan cross sectional. Populasi penelitian ini adalah air minum isi ulang sebanyak 8 sampel dan sumbernya sebanyak 8 sampel dengan teknik pengambilan sampel secara total sampling. Berdasarkan hasil pemeriksaan MPN pada air minum isi ulang 87,5% positif dan pada sumbernya 100% positif. Beberapa faktor yang dapat mempengaruhi kualitas tingginya nilai MPN Coliform pada air sumur yaitu tidak memiliki surat jaminan pasokan baku dari PDAM, penggunaan air baku yang bersih dan konstruksi sumur tidak sesuai dengan standar kesehatan. Faktor yang dapat menyebabkan tercemarnya air sumur tidak mempunyai surat hygiene sanitasi dari Dinas Kesehatan, tidak memiliki laporan hasil uji laboratorium tentang pemeriksaan kualitas air, pencucian hanya menggunakan sikat seharusnya menggunakan UV dan filter serta rendahnya tingkat pengetahuan responden terhadap air bersih. Kata kunci : air minum, cemaran, MPN Coliform ABSTRACT MPN Coliform IN REFIL DRINKING WATER IN SUB DISTRICTS OF SAMBUNG MAKMUR Nor Yatun Putri Kartika Sari, Dewi Ramadhani Drinking water are water that through the process of processing or without processing that meet health requirements can be drunk directly. According to the Minister of Health of the Republic of Indonesia No. 492 / Menkes / PER / 1V / 2010 drinking water quality requirements include bacteriological, chemical, physical and radiological requirements. This study aims to determine the value of MPN Coliform in drinking water refill and its source in District Sambung Makmur. This research is descriptive survey with cross sectional design. The population of this study is refill drinking water and the source is 8 and water samples source 8 with sampling technique in total sampling. Based on the results of MPN examination on drinking water refill 87,5% positive and at the source 100% positive. Several factors that can affect the high quality of MPN Coliform value in well water that is not having the guarantee letter of raw supply from PDAM, the use of clean raw water and well construction is not in accordance with health standard. Factors that can cause contamination of well water do not have sanitary hygiene letter from Health Department, do not have report of laboratory test result about water quality inspection, only brush leaching should use UV and filter and low level of knowledge of respondent to clean water. Keywords: drinking water, contamination, MPN Coliform 

Institution Info

Sekolah Tinggi Ilmu Kesehatan Borneo Lestari