DETAIL DOCUMENT
Analisis Resiko Yang Mempengaruhi Tingkat Air Ketel Uap Dari Imbibisi Air Kondensat PG. Pesantren Baru Dengan Menggunakan Metode FMEA Dan FTA
Total View This Week0
Institusion
Universitas Kadiri
Author
Rowi, Saiful
Subject
TS Manufactures 
Datestamp
2022-01-25 01:59:13 
Abstract :
PG. Pesantren Baru is one of the industrial companies that produce sugar for the needs of people in Kediri City and national. The purpose of this research is to know the factors that inhibit the rate of supply of dew water (condensate water) to the boiler and how it is handled using Failure Mode and Effect Analysis (FMEA) and Fault Tree Analysis (FTA) methods. The scope and limitation of problems on this research is only done on boiler stations and more leads to dew water supply (condensate water) on the boiler machine Yoshimine II. The data used in this research is the primary data and secondary data from the company. With data collection techniques include observation, interviews and library studies. From the research results obtained 5 constraints that have been identified by the FMEA method. From 5 constraints gained 2 top events that have occurred during the operation process in the area of water flow imbibisi at the grind station PG. Pesantren Baru in 2018-2019. The first ranking is on the constraints of the pump to distribute the water Imbibisi to the APK tank suffered damage with RPN at 18. The second ranking is on the obstacles of the water crust many are attached to the wall pipe evaporation body with RPN at 8. Keywords : Failure Mode and Effect Analysis, Fault Tree Analysis, Risk Priority Number 
Institution Info

Universitas Kadiri