DETAIL DOCUMENT
ANALISA PENEKANAN LOSSES NON TEKNIS MELALUI OPTIMALISASI PENGGUNAAN ADVANCED METERING INFRASTRUCTURE (AMI) DI PT PLN (PERSERO) UP3 PONDOKKOPI
Total View This Week0
Institusion
Institut Teknologi Perusahaan Listrik Negara
Author
Roihan, Muhammad Firdaus
Purwanto, Sugeng
Subject
Teknik Elektro 
Datestamp
2023-06-19 07:07:33 
Abstract :
Losses or better known as "shrinkage" is a parameter that must be considered by PT PLN (Persero), because this parameter shows how well the efficiency of a system is. Network losses at UP3 Pondok Kopi UID Jakarta Raya until February 2022 amounted to 8.73%. Meanwhile, the target for losses by the end of 2022 is 8.13%. With the loss target not being achieved at UP3 Pondok Kopi, it is necessary to conduct research to reduce losses, one of which can be through improving meter reading accuracy by replacing the existing kWh meter with AMI kWh meter to reduce non-technical losses. In this research, the existing kWh meter was replaced which still uses a mechanical kWh meter with a Smart Meter called the Advanced Metering Infrastructure (AMI), then continued with a comparative analysis study of losses before and after the use of the Advanced Metering Infrastructure (AMI). The results of this study were that there was a decrease in losses at the PL-25 substation by 0.19% after replacing the mechanical kWh meter with Advanced Metering Infrastructure (AMI). 
Institution Info

Institut Teknologi Perusahaan Listrik Negara